Patiala/Ludhiana, 18 Nov 2026: Firms have complained to the PSPCL CMD, PSERC and the Vigilance Wing that Metering Organisation officials violated the PSPCL Purchase Regulations, 2017 in Tender Enquiry No. MQP-267/26-27/PO(M) (Tender ID 2026_POWER_172497_1) for Power Quality (PQ) meters, alleging a scam worth crores. Industry also says the same organisation has not acted on an IIT Ropar report that would reduce Total Demand Distortion (TDD) penalties on PQ meter consumers.

Alleged tender violations

Clause 10(a)(iv): Pre-Bid Meeting (29.07.2026) queries and clarifications were not uploaded on the e-tendering portal and minutes were not circulated to all bidders, also against the Punjab Transparency in Public Procurement Act, 2012.
Clause 10(xi): Downloads must stop 24 hours before bid opening, but bids closed on 25.09.2026 at 11:30 AM and were opened the same day at about 4:00 PM (under five hours), allowing last-moment proxy bids.
Transparency: Bid dates were extended nine times in seven weeks without written reasons, including after bids were received, allegedly to defeat competition.
Price break-up module: Left out, unlike earlier tenders such as No. 246; a break-up provision was briefly added, then withdrawn unexplained.
Specification: An Indian Standard was included, then withdrawn, allegedly under pressure from past suppliers. Reputed firms stayed away.
Wrongful rejection: One firm’s bid was rejected for not submitting samples, though samples are due only after bid opening.

Sealing provision, type test report, dimensions

Elmeasure India wrote to the Data Assessment Committee (DAC), headed by Er. Rajiv Sumra, SE/P&M Jalandhar, that the Janitza PQ meter sample, sealed through a front-face hole, fails Clauses 29.1 and 30.0 of the specification. It says there is no proper sealing provision, the hole is not in the type-tested design, and no cyber security evidence or meter box type-test report was furnished.
In its letter to the CMD, Elmeasure says the bidder’s ServiceForce.Com GmbH report (No. SFC_013_14E) is dated 18.03.2014, yet one test (Damped Oscillatory Waves, item 4.2.8) cites IEC/EN 61000-4-12:2017, a 2017 standard. It argues the report appears to have been altered after issue.
The complainants also say the Janitza meter supplied has a depth of 75 mm against the 175 mm quoted in the Guaranteed Technical Particulars (GTP), yet it was cleared by the DAC and PSPCL ME Labs without any checking against MQP-194.
They allege the meters were cleared despite these defects and that the Purchase Regulations, tender conditions and other rules were bypassed.

IIT Ropar report on ISC/IL

Large industrial (PIU) consumers with PQ meters are allegedly being penalised for TDD on an improper assessment of Short Circuit Current (ISC) and Load Current (IL), a methodology the CE/Metering office itself doubted. It placed Work Order No. 5 dated 21.11.2024 on IIT Ropar, which submitted its reviewed methodology in December 2025, under which TDD penalties have to be revised.

Almost a year on, no action has been taken, and penalties on the old assessment continue. Many consumers installed power quality monitoring and mitigation equipment they may not have needed, at a loss of crores. The complainants question why Metering is pushing through a PQ meter purchase in haste while sitting on the report.